Perusahaan Ini Telah Berdiri Sejak Tahun 2010 dan Telah Ikut Berkiprah Dalam Kancah Kelistrikan di Indonesia. Kami Menyediakan Barang dan Jasa, Sebagai Sebuah Perusahaan Yang Bergerak di Bidang Supplier dan Contractor Electrical Kami Selalu Mengutamakan Kepuasan Costumer Jangan Ragu Untuk Menghubungi Kami

Detail SIL-A OC&EF Line Protection Relay

Overcurrent and Earth Fault Protection Relay for Primary and Secondary Distribution

The current measurement is obtained either by standard current transformers /1 or /5, or by special Low Power Current Transformers (LPCT).

Main characteristics:

  • Many Protection functions by default: 50P(2), 50N/G(2)(*), 50/51P, 50/51 N/G(*), 50BF, 46, 52, 79, 74TCS, COLD LOAD PICK-UP, 86, 49T . Optionally 49, 74CT, 37, 46BC, Trip Block for switch disconnector.
  • SIL-A adaptation B with Trip Bus protection function available through configurables inputs and outputs.
  • Auxiliary power supply (110-230 Vac/90-300 Vdc, 24-48 Vdc or 24-110 Vdc/48-230 Vac).
  • Metallic Box with high electromagnetic compatibility level (EMC) and wide range of operating temperature.
  • Reduced size and light weight, easy to install and saves costs.
  • Direct signalling/control of circuit breaker (52 function) and recloser (79 function).
  • To allow communication, relays have a communication port on the front of the equipment and remote communication with different options:
    • One rear port on the back with the following options respect to protocols:
      • IEC60870-103 or Modbus RTU selectable by settings
      • IEC 61850, DNP3.0 or IEC 60870-5-104 (depending on the model)
    • Two rear ports on can be used simultaneously:
      • ModBus RTU and IEC60870-5-103, IEC 61850, DNP 3.0 or IEC 60870-5-104.
  • Inputs and outputs configurable, trip circuit supervision (74TCS function).
  • Oscillographic records, fault reports and non-volatile RAM memory: stores multiple events with date/time even without power supply thanks to its internal RTC.
  • Adaptation B is fitte with the demand of current with; 168 records, circular mode of recording and sampling rate (configurable through communications from 1 to 60 minutes)

(*) LPCT model: neutral current is calculated so overcurrent protection functions are 50N(2) and 50/51N.

(*) Compact model: neutral current is measured so overcurrent protection functions are 50N/G(2), 50/51 N/G